| Place of Origin: | China | 
|---|---|
| Brand Name: | MICH | 
| Certification: | ISO9001 | 
| Model Number: | MIHTCOTT | 
| Minimum Order Quantity: | 1 meter | 
| Price: | USD0.5-USD5 per meter | 
| Packaging Details: | plywood crates | 
| Delivery Time: | in one month | 
| Supply Ability: | 10 million meters per year | 
| Use: | Tanker Pipeline | Media: | Crude Oil | 
|---|---|---|---|
| Insulation: | High Purity Magnesium Oxide | Usage: | Heat Tracing | 
| Min. Bend Radius: | 6 X Cable Diameter | Max. Maintenance Temp. (°F): | 900 | 
| Max. Exposure Temp. (°F) Power Off: | 1100 | Voltages: | Up To 600 | 
| Highlight: | 600V Electric Heat Tracing,Mineral Insulated Electric Heat Tracing,600V heat tracing system | ||
Mineral Insulated Heat Trace Cable for Oil Transportation Marine Tanker is a specially designed heat tracer for the crude oil pipeline on the tanker vessel to be used to make the oil in a liquid form so that it can help load and unload conveniently and fast.
Specification
Heating cable instruction code
MI CU-B 16K320/60/2520/220/E1
No. 1 2 3 4 5 6 7
| No. | Instruction | |
| 1 | Sheath material | CU | 
| 2 | structure of cable components | shown in table 1 | 
| 3 | cable codes | shown in table 2, 3 and 4 | 
| 4 | length of heating cable | In meter | 
| 5 | Heating cable power | In Watt | 
| 6 | heating cable voltage | In Volt | 
| 7 | heating cable voltage | See table 5 | 
Cable Code
1 6 K 320
No. 1 2 3 4
| Serial NO. | Instruction | |
| 1 | core number | 1 or 2 | 
| 2 | Voltage grade | 3=300V, 6=600V | 
| 3 | conductor materials | C,K | 
| 4 | cold resistance ×1000 | 320=0.32Ω/m×1000 | 
Table 1 Structure of Cable Element

Note: Model C, F and G are suitable for being used at temperature under 65℃
Table 2 Heating Cable Specification (600V Single Conductor)
| Cable Code | Diameter | HDPE Diameter | Standard resistance value at +20℃ | Maximum Production Length | Unit weight | 
| mm | mm | Ω/m | m | kg/km | |
| 16C1.7 | 8.2 | 10 | 0.0017 | 350 | 366.54 | 
| 16C2.2 | 7.6 | 9.4 | 0.0022 | 380 | 307.77 | 
| 16C2.9 | 7.0 | 8.8 | 0.0029 | 400 | 264.45 | 
| 16C4 | 5.9 | 7.7 | 0.004 | 600 | 190.88 | 
| 16C7 | 5.3 | 7.1 | 0.007 | 600 | 154.08 | 
| 16C11 | 4.9 | 6.7 | 0.011 | 600 | 132.25 | 
| 16C13 | 4.6 | 6.4 | 0.013 | 600 (300)☆ | 125.7 | 
| 16C17 | 4.6 | 6.4 | 0.017 | 600 (300)☆ | 117.16 | 
| 16C21 | 4.6 | 6.4 | 0.021 | 600 (300)☆ | 111.9 | 
| 16C25 | 3.7 | 5.5 | 0.025 | 600 (480)☆ | 68.83 | 
| 16C33 | 3.7 | 5.5 | 0.033 | 600 (480)☆ | 63.76 | 
| 16C40 | 3.4 | 5.2 | 0.04 | 600 (560)☆ | 58.87 | 
| 16C63 | 3.2 | 5 | 0.063 | 600 | 51.47 | 
| 16K80 | 6.8 | 8.6 | 0.08 | 370 (140)☆ | 254.18 | 
| 16K100 | 5.2 | 7 | 0.1 | 450 (240)☆ | 162.11 | 
| 16K140 | 4.9 | 6.7 | 0.14 | 600 (270)☆ | 122.55 | 
| 16K197 | 4.45 | 6.25 | 0.197 | 600 (330)☆ | 111.32 | 
| 16K220 | 4.5 | 6.3 | 0.22 | 600 (330)☆ | 102.89 | 
| 16K315 | 4.3 | 6.1 | 0.315 | 600 (350)☆ | 91.44 | 
| 16K345 | 4.2 | 6.0 | 0.345 | 600 (370)☆ | 85.9 | 
| 16K450 | 4.0 | 5.8 | 0.45 | 600 (400)☆ | 80.73 | 
| 16K630 | 4.0 | 5.8 | 0.63 | 600 (400)☆ | 77.26 | 
| 16K800 | 3.5 | 5.3 | 0.8 | 600 (530)☆ | 61.48 | 
| 16K1250 | 2.8 | 4.6 | 1.25 | 600 | 40.83 | 
| 16K2000 | 2.8 | 4.6 | 2.0 | 600 | 38.96 | 
Table 3 Heating Cable Specification (600V Double Conductors)
| Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight | 
| mm | Ω/m | m | kg/km | |
| 26C3.4 | 12.9 | 0.0034 | 150 | 783.76 | 
| 26C4.4 | 12.2 | 0.0044 | 160 | 701.56 | 
| 26C5.8 | 11.3 | 0.0058 | 170 | 606.16 | 
| 26C8.6 | 9.90 | 0.0086 | 180 | 451.43 | 
| 26C11.4 | 9.30 | 0.0114 | 200 | 400.05 | 
| 26C13.8 | 9.00 | 0.0138 | 210 | 375.20 | 
| 26C17.2 | 8.60 | 0.0172 | 220 | 344.90 | 
| 26C23 | 8.00 | 0.023 | 250 | 303.25 | 
| 26C34.4 | 7.50 | 0.0344 | 280 | 269.20 | 
| 26C49.2 | 7.10 | 0.0492 | 300 | 243.84 | 
| 26K240 | 9.90 | 0.24 | 180 | 451.43 | 
| 26K320 | 9.30 | 0.32 | 200 | 400.05 | 
| 26K384 | 9.00 | 0.384 | 210 | 375.20 | 
| 26K480 | 8.60 | 0.48 | 220 | 344.90 | 
| 26K640 | 8.00 | 0.64 | 250 | 303.25 | 
| 26K960 | 7.50 | 0.96 | 280 | 269.20 | 
Table 4 Heating Cable Specification (300V Double Cores)
| Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight | 
| mm | Ω/m | m | kg/km | |
| 23C3.4 | 12.0 | 0.0034 | 200 | 708.10 | 
| 23C4.4 | 11.3 | 0.0044 | 220 | 629.07 | 
| 23C5.8 | 10.4 | 0.0058 | 240 | 537.73 | 
| 23C8.6 | 9.00 | 0.0086 | 260 | 392.56 | 
| 23C11.4 | 8.40 | 0.0114 | 280 | 343.89 | 
| 23C13.8 | 8.00 | 0.0138 | 300 | 314.57 | 
| 23C17.2 | 7.60 | 0.0172 | 320 | 286.27 | 
| 23C23 | 7.10 | 0.023 | 340 | 252.98 | 
| 23C34.4 | 6.60 | 0.0344 | 360 | 221.19 | 
| 23C49.2 | 6.20 | 0.0492 | 380 | 197.64 | 
| 23K160 | 10.4 | 0.16 | 220 | 508.37 | 
| 23K240 | 9.00 | 0.24 | 240 | 392.56 | 
| 23K320 | 8.40 | 0.32 | 265 | 343.89 | 
| 23K384 | 8.00 | 0.384 | 280 | 314.57 | 
| 23K480 | 7.70 | 0.48 | 300 | 291.91 | 
| 23K640 | 7.10 | 0.64 | 320 | 252.98 | 
| 23K960 | 6.50 | 0.96 | 350 | 216.11 | 
Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);
For the use of 660V voltage occasions, please contact our company professionals;
Mark of (300)☆ is a recommended production length by MICH
Table 5 terminal specifications
| Model: A, D, E | Model: B | |||||
| Maximum Voltage(V) | Maximum Current (A) | Terminal Specification | Maximum Voltage(V) | Maximum Current (A) | Terminal Specification | Maximum Voltage(V) | 
| 600 | 15 | E2 | 20 | E1 | 15 | E1 | 
| 600 | 20 | E2 | 25 | E2 | 20 | E1 | 
| 600 | 30 | E3 | 40 | E2 | 30 | E2 | 
| 600 | 50 | E3 | 70 | E2 | 50 | E2 | 
| 600 | 70 | E3 | 100 | E3 | 70 | E2 | 
Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.
Corresponding reference table between the output power and sheath temperature

Note: when applying a copper conductor heating cable, please pay attention to the conversion of its heated hot resistance and unheated cold resistance.
Anticorrosive specification
| Material | MICU | MIHC | 
| Sulfate | Not recommend | Excellent | 
| Hydrochloric acid | Not recommend | Excellent | 
| Hydrofluoric acid | Acceptable | Acceptable | 
| Phosphate | Acceptable | Acceptable | 
| Carbonate | Not recommend | Acceptable | 
| Organic acid | Acceptable | Not recommend | 
| Alkali metal | Acceptable | Acceptable | 
| Sea water | Not recommend | Acceptable | 
| Chloride | Data checking required | Acceptable | 
Explosion-proof instructions
MIAL series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to Ⅱ A, Ⅱ B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.