Place of Origin: | China |
---|---|
Brand Name: | MICH |
Certification: | ISO9001 |
Model Number: | MIHCCSLD |
Minimum Order Quantity: | 1 meter |
Price: | USD0.5-USD5 per meter |
Packaging Details: | plywood crates |
Delivery Time: | in one month |
Payment Terms: | L/C, T/T |
Supply Ability: | 20 million meters |
Sheath: | Copper | Function: | Freeze Prevention |
---|---|---|---|
Application: | Metal Gutters And Downpipes | Diameter: | Up To Project Request |
Cable Length: | In Meter | Power: | In Watt |
Vottage: | Volt | Unit Weight: | Up To 184 Kg/km |
High Light: | Antifreeze Mineral Insulated Copper Sheathed Cable,250 ℃ Mineral Insulated Copper Sheathed Cable,600V mi heating cable |
Copper Sheathed MI Heating Cable for Freeze Prevention for Metal Gutters and Downpipes can meet the needs of high temperature condition and heat tracing of long-distance transportation pipeline. The maximum withstand temperature of the copper sheathed heating cable (MICU) provided by MICH can reach up to 250℃. Conductor resistance value ranges from 1.7-2000Ω/km. For the occasion of anti-corrosion or buried application, high density polyethylene (HDPE) outer sheath ( cable known as MIHC) is needed to be added. MIHC’s withstanding maximum temperature can be up to 90℃. Mineral insulated heating cable possesses excellent mechanical strength. The heating cable of series resistance provided by MICH can meet the requirements of different power levels.
Cable Structure
Application
Copper sheathed heating cable (MICU) | Maximum output power(W/m) |
Freezing Prevention for metal gutters and downpipes | 49 |
Freezing Prevention for non-metal gutters and downpipes | 16 |
Vessel and piping process temperature maintaining | 59 |
Freezing Prevention for metal containers and pipes | 59 |
Metal roof snow-melting | 49 |
High-density polyethylene outer sheathed copper sheathed heating cable (MIHC) | |
Freezing Prevention for metal containers and pipes | 26 |
Freezing Prevention non-metallic containers and pipes | 13 |
Snow melting on asphalt slopes | 82 |
Non-metallic roof ice or snow melting | 26 |
Freezing Prevention for metal gutters and downpipes | 26 |
Freezing Prevention for non - metallic gutters and downpipes | 16 |
Concrete floor heating | 33 |
Rising or defrosting prevention for cold storage ground | 23 |
Freezing Prevention for metal containers and pipes | 99 |
Note: when heating cables are used for heat tracing of vessels and pipes, the maximum output power must be controlled to ensure that the sheath temperature does not exceed its maximum allowable temperature or the spontaneous combustion temperature of the area (for hazardous areas).
Specification
Heating cable instruction code
MI CU-B 16K320/60/2520/220/E1
No. 1 2 3 4 5 6 7
No. | Instruction | |
1 | Sheath material | CU |
2 | structure of cable components | shown in table 1 |
3 | cable codes | shown in table 2, 3 and 4 |
4 | length of heating cable | In meter |
5 | Heating cable power | In Watt |
6 | heating cable voltage | In Volt |
7 | heating cable voltage | See table 5 |
Cable Code
1 6 K 320
No. 1 2 3 4
Serial NO. | Instruction | |
1 | core number | 1 or 2 |
2 | Voltage grade | 3=300V, 6=600V |
3 | conductor materials | C,K |
4 | cold resistance ×1000 | 320=0.32Ω/m×1000 |
Table 1 Structure of Cable Element
Note: Model C, F and G are suitable for being used at temperature under 65℃
表格 2 加热电缆规格 (600V 单芯)
Cable Code | Diameter | HDPE Diameter | Standard resistance value at +20℃ | Maximum Production Length | Unit weight |
mm | mm | Ω/m | m | kg/km | |
16C1.7 | 8.2 | 10 | 0.0017 | 350 | 366.54 |
16C2.2 | 7.6 | 9.4 | 0.0022 | 380 | 307.77 |
16C2.9 | 7.0 | 8.8 | 0.0029 | 400 | 264.45 |
16C4 | 5.9 | 7.7 | 0.004 | 600 | 190.88 |
16C7 | 5.3 | 7.1 | 0.007 | 600 | 154.08 |
16C11 | 4.9 | 6.7 | 0.011 | 600 | 132.25 |
16C13 | 4.6 | 6.4 | 0.013 | 600 (300)☆ | 125.7 |
16C17 | 4.6 | 6.4 | 0.017 | 600 (300)☆ | 117.16 |
16C21 | 4.6 | 6.4 | 0.021 | 600 (300)☆ | 111.9 |
16C25 | 3.7 | 5.5 | 0.025 | 600 (480)☆ | 68.83 |
16C33 | 3.7 | 5.5 | 0.033 | 600 (480)☆ | 63.76 |
16C40 | 3.4 | 5.2 | 0.04 | 600 (560)☆ | 58.87 |
16C63 | 3.2 | 5 | 0.063 | 600 | 51.47 |
16K80 | 6.8 | 8.6 | 0.08 | 370 (140)☆ | 254.18 |
16K100 | 5.2 | 7 | 0.1 | 450 (240)☆ | 162.11 |
16K140 | 4.9 | 6.7 | 0.14 | 600 (270)☆ | 122.55 |
16K197 | 4.45 | 6.25 | 0.197 | 600 (330)☆ | 111.32 |
16K220 | 4.5 | 6.3 | 0.22 | 600 (330)☆ | 102.89 |
16K315 | 4.3 | 6.1 | 0.315 | 600 (350)☆ | 91.44 |
16K345 | 4.2 | 6.0 | 0.345 | 600 (370)☆ | 85.9 |
16K450 | 4.0 | 5.8 | 0.45 | 600 (400)☆ | 80.73 |
16K630 | 4.0 | 5.8 | 0.63 | 600 (400)☆ | 77.26 |
16K800 | 3.5 | 5.3 | 0.8 | 600 (530)☆ | 61.48 |
16K1250 | 2.8 | 4.6 | 1.25 | 600 | 40.83 |
16K2000 | 2.8 | 4.6 | 2.0 | 600 | 38.96 |
Table 3 Heating Cable Specification (600V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
26C3.4 | 12.9 | 0.0034 | 150 | 783.76 |
26C4.4 | 12.2 | 0.0044 | 160 | 701.56 |
26C5.8 | 11.3 | 0.0058 | 170 | 606.16 |
26C8.6 | 9.90 | 0.0086 | 180 | 451.43 |
26C11.4 | 9.30 | 0.0114 | 200 | 400.05 |
26C13.8 | 9.00 | 0.0138 | 210 | 375.20 |
26C17.2 | 8.60 | 0.0172 | 220 | 344.90 |
26C23 | 8.00 | 0.023 | 250 | 303.25 |
26C34.4 | 7.50 | 0.0344 | 280 | 269.20 |
26C49.2 | 7.10 | 0.0492 | 300 | 243.84 |
26K240 | 9.90 | 0.24 | 180 | 451.43 |
26K320 | 9.30 | 0.32 | 200 | 400.05 |
26K384 | 9.00 | 0.384 | 210 | 375.20 |
26K480 | 8.60 | 0.48 | 220 | 344.90 |
26K640 | 8.00 | 0.64 | 250 | 303.25 |
26K960 | 7.50 | 0.96 | 280 | 269.20 |
Table 4 Heating Cable Specification (300V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
23C3.4 | 12.0 | 0.0034 | 200 | 708.10 |
23C4.4 | 11.3 | 0.0044 | 220 | 629.07 |
23C5.8 | 10.4 | 0.0058 | 240 | 537.73 |
23C8.6 | 9.00 | 0.0086 | 260 | 392.56 |
23C11.4 | 8.40 | 0.0114 | 280 | 343.89 |
23C13.8 | 8.00 | 0.0138 | 300 | 314.57 |
23C17.2 | 7.60 | 0.0172 | 320 | 286.27 |
23C23 | 7.10 | 0.023 | 340 | 252.98 |
23C34.4 | 6.60 | 0.0344 | 360 | 221.19 |
23C49.2 | 6.20 | 0.0492 | 380 | 197.64 |
23K160 | 10.4 | 0.16 | 220 | 508.37 |
23K240 | 9.00 | 0.24 | 240 | 392.56 |
23K320 | 8.40 | 0.32 | 265 | 343.89 |
23K384 | 8.00 | 0.384 | 280 | 314.57 |
23K480 | 7.70 | 0.48 | 300 | 291.91 |
23K640 | 7.10 | 0.64 | 320 | 252.98 |
23K960 | 6.50 | 0.96 | 350 | 216.11 |
Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);
For the use of 660V voltage occasions, please contact our company professionals;
Mark of (300)☆ is a recommended production length by MICH
Table 5 terminal specifications
Model: A, D, E | Model: B | |||||
Maximum Voltage(V) | Maximum Current (A) | Terminal Specification | Maximum Voltage(V) | Maximum Current (A) | Terminal Specification | Maximum Voltage(V) |
600 | 15 | E2 | 20 | E1 | 15 | E1 |
600 | 20 | E2 | 25 | E2 | 20 | E1 |
600 | 30 | E3 | 40 | E2 | 30 | E2 |
600 | 50 | E3 | 70 | E2 | 50 | E2 |
600 | 70 | E3 | 100 | E3 | 70 | E2 |
Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.
Corresponding reference table between the output power and sheath temperature
Note: when applying a copper conductor heating cable, please pay attention to the conversion of its heated hot resistance and unheated cold resistance.
Anticorrosive specification
Material |
MICU |
MIHC |
Sulfate | Not recommend | Excellent |
Hydrochloric acid | Not recommend | Excellent |
Hydrofluoric acid | Acceptable | Acceptable |
Phosphate | Acceptable | Acceptable |
Carbonate | Not recommend | Acceptable |
Organic acid | Acceptable | Not recommend |
Alkali metal | Acceptable | Acceptable |
Sea water | Not recommend | Acceptable |
Chloride | Data checking required | Acceptable |
Explosion-proof instructions
MIAL series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to Ⅱ A, Ⅱ B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.
MI CU-B 16K320/60/2520/220/E1
No. 1 2 3 4 5 6 7