Place of Origin: | China |
---|---|
Brand Name: | MICH |
Certification: | ISO9001 |
Model Number: | EHTTSOTU |
Minimum Order Quantity: | 1 meter |
Price: | USD0.5-USD5 per meter |
Packaging Details: | plywood crates |
Delivery Time: | in one month |
Supply Ability: | 10 million meters per year |
Dimensions: | 0.2"x0.3" (5mm X 8mm) 12 AWG | Dielectric Strength: | Over 2000 Volts |
---|---|---|---|
Property: | Explosion-proof, Anti-corrosion, Safe | Usage: | Oil Terminal |
Distance: | Up To Long Distance | Wattage: | 39Watt/meter |
Max. Exposure Temp. (°F) Power Off: | 260 | Voltages: | Up To 480 |
High Light: | 2000V Pipe Tracing Heating Tape Cables,Anti Corrosion pipe tracing heating tape cables,2000V heating cables for pipes |
Electric Heat Tracing Technical Solution for Oil Terminal Use is an electric heat trace technology package which can be selected to be used on the pipelines, tanks, valves etc related to the oil terminals based on the project conditions and requirement. In winter, the climate is cold and the temperature is too low, which may lead to serious blockage of the oil pipeline when it arrives at the gathering and transmission pump station due to the heat loss and wind speed, etc., and the material in the pipeline cannot be normally transported. In order to solve the problem of oil pipeline freezing, the electric heat tracing solution should be used to heat all the main pipelines on the wharf.
Through the field investigation, including the local temperature, low temperature, wind speed, and from the safety point of view, for the long oil transmission pipeline of large diameter, the occasion of high heat tracking temperature, and combined with the heat loss of comprehensive consideration, the constant power electric heating trace should be used, because the highest maintenance temperature can reach 150℃, and the highest exposure temperature is 205 degrees, which can completely maintain the normal operation of the oil pipeline. For longer pipelines, the use of series constant power electric heating insulation products, the electric tracing is large and the service length is longer, up to thousands of meters. While for the transmission distance is not long, for higher safety, corrosion resistance consideration and other high requirements, mineral insulation heating cable can be considered. For the distance to be at least 5 kilometers, the skin effect heating solution can be considered.
The series constant power electric heating tracing product is 5~12 times longer than the general constant power and self-limiting temperature electric tracing, so it is especially suitable for long distance transmission pipelines in petroleum, chemical industry, electric power, wharf and other industries.
In the performance of electric heat trace products, the outer layer of electric tracing belt has metal shielding braided layer, which not only has the function of heat transfer and heat dissipation, but also can improve the overall tensile strength of electric heating, and can also be used as a safe grounding wire.
Table 2 Heating Cable Specification (600V Single Conductor)
Cable Code | Diameter | HDPE Diameter | Standard resistance value at +20℃ | Maximum Production Length | Unit weight |
mm | mm | Ω/m | m | kg/km | |
16C1.7 | 8.2 | 10 | 0.0017 | 350 | 366.54 |
16C2.2 | 7.6 | 9.4 | 0.0022 | 380 | 307.77 |
16C2.9 | 7.0 | 8.8 | 0.0029 | 400 | 264.45 |
16C4 | 5.9 | 7.7 | 0.004 | 600 | 190.88 |
16C7 | 5.3 | 7.1 | 0.007 | 600 | 154.08 |
16C11 | 4.9 | 6.7 | 0.011 | 600 | 132.25 |
16C13 | 4.6 | 6.4 | 0.013 | 600 (300)☆ | 125.7 |
16C17 | 4.6 | 6.4 | 0.017 | 600 (300)☆ | 117.16 |
16C21 | 4.6 | 6.4 | 0.021 | 600 (300)☆ | 111.9 |
16C25 | 3.7 | 5.5 | 0.025 | 600 (480)☆ | 68.83 |
16C33 | 3.7 | 5.5 | 0.033 | 600 (480)☆ | 63.76 |
16C40 | 3.4 | 5.2 | 0.04 | 600 (560)☆ | 58.87 |
16C63 | 3.2 | 5 | 0.063 | 600 | 51.47 |
16K80 | 6.8 | 8.6 | 0.08 | 370 (140)☆ | 254.18 |
16K100 | 5.2 | 7 | 0.1 | 450 (240)☆ | 162.11 |
16K140 | 4.9 | 6.7 | 0.14 | 600 (270)☆ | 122.55 |
16K197 | 4.45 | 6.25 | 0.197 | 600 (330)☆ | 111.32 |
16K220 | 4.5 | 6.3 | 0.22 | 600 (330)☆ | 102.89 |
16K315 | 4.3 | 6.1 | 0.315 | 600 (350)☆ | 91.44 |
16K345 | 4.2 | 6.0 | 0.345 | 600 (370)☆ | 85.9 |
16K450 | 4.0 | 5.8 | 0.45 | 600 (400)☆ | 80.73 |
16K630 | 4.0 | 5.8 | 0.63 | 600 (400)☆ | 77.26 |
16K800 | 3.5 | 5.3 | 0.8 | 600 (530)☆ | 61.48 |
16K1250 | 2.8 | 4.6 | 1.25 | 600 | 40.83 |
16K2000 | 2.8 | 4.6 | 2.0 | 600 | 38.96 |
Table 3 Heating Cable Specification (600V Double Conductors)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
26C3.4 | 12.9 | 0.0034 | 150 | 783.76 |
26C4.4 | 12.2 | 0.0044 | 160 | 701.56 |
26C5.8 | 11.3 | 0.0058 | 170 | 606.16 |
26C8.6 | 9.90 | 0.0086 | 180 | 451.43 |
26C11.4 | 9.30 | 0.0114 | 200 | 400.05 |
26C13.8 | 9.00 | 0.0138 | 210 | 375.20 |
26C17.2 | 8.60 | 0.0172 | 220 | 344.90 |
26C23 | 8.00 | 0.023 | 250 | 303.25 |
26C34.4 | 7.50 | 0.0344 | 280 | 269.20 |
26C49.2 | 7.10 | 0.0492 | 300 | 243.84 |
26K240 | 9.90 | 0.24 | 180 | 451.43 |
26K320 | 9.30 | 0.32 | 200 | 400.05 |
26K384 | 9.00 | 0.384 | 210 | 375.20 |
26K480 | 8.60 | 0.48 | 220 | 344.90 |
26K640 | 8.00 | 0.64 | 250 | 303.25 |
26K960 | 7.50 | 0.96 | 280 | 269.20 |
Table 4 Heating Cable Specification (300V Double Cores)
Cable Code | Diameter | Nominal resistance at +20℃ | Maximum manufacturing length | Unit weight |
mm | Ω/m | m | kg/km | |
23C3.4 | 12.0 | 0.0034 | 200 | 708.10 |
23C4.4 | 11.3 | 0.0044 | 220 | 629.07 |
23C5.8 | 10.4 | 0.0058 | 240 | 537.73 |
23C8.6 | 9.00 | 0.0086 | 260 | 392.56 |
23C11.4 | 8.40 | 0.0114 | 280 | 343.89 |
23C13.8 | 8.00 | 0.0138 | 300 | 314.57 |
23C17.2 | 7.60 | 0.0172 | 320 | 286.27 |
23C23 | 7.10 | 0.023 | 340 | 252.98 |
23C34.4 | 6.60 | 0.0344 | 360 | 221.19 |
23C49.2 | 6.20 | 0.0492 | 380 | 197.64 |
23K160 | 10.4 | 0.16 | 220 | 508.37 |
23K240 | 9.00 | 0.24 | 240 | 392.56 |
23K320 | 8.40 | 0.32 | 265 | 343.89 |
23K384 | 8.00 | 0.384 | 280 | 314.57 |
23K480 | 7.70 | 0.48 | 300 | 291.91 |
23K640 | 7.10 | 0.64 | 320 | 252.98 |
23K960 | 6.50 | 0.96 | 350 | 216.11 |
Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);
For the use of 660V voltage occasions, please contact our company professionals;
Mark of (300)☆ is a recommended production length by MICH
Selection Parameters:
Constant Wattage Heating Cable | High Temperature Heating cable | Polyamide/Fiberglass Heating Cable | Harsh Environment Heating Cable | General Purpose Heating Cable |
Available Voltages | 120, 208, 240, 277 & 480 VAC | 120, 208, 240, 277 & 480 VAC | 120, 208, 240, 277 & 480 VAC | 120, 208, 240, 277 & 480 VAC |
Available Wattages
|
4, 8 & 12 watts/ft (13, 26 & 39 watts/m) | 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) | 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) | 3, 5, 8 & 12 watts/ft (10, 16, 26 & 39 watts/m) |
Maximum Exposure Temperature |
500°F (260°C)
|
500°F (260°C)
|
500°F (260°C)
|
400°F (204°C)
|
Nominal Dimensions
|
0.2"x0.3" (5mm x 8mm) 12 AWG
|
0.2"x0.3" (5mm x 8mm) 12 AWG
|
0.2"x0.3" (5mm x 8mm) 12 AWG
|
0.2"x0.3" (5mm x 8mm) 12 AWG |
Resistance to Moisture | Good | Good |
Excellent
|
Excellent
|
Resistance to Chemicals | Good | Good |
Excellent
|
Excellent
|
Resistance to Flame | Excellent | Outstanding | Excellent | Outstanding |
Dielectric Strength | Over 2000 volts |
Over 2000 volts
|
Over 2000 volts | Over 2000 volts |